ARG16R16-0,6/1 kV 1 x 95
Certifications and labels
ARG16R16-0,6/1 kV 1 x 95
Suitable for the transport of power in the industry, construction sites and housing. For static use outdoor and indoor, in brickwork, metal structures, gangways, pipes, ducts or similar closed systems. Allowed for underground laying also unprotected.
Read more- Nexans ref. : 557037144
Description
Description
Standards
-
ProductCEI 20-13; CEI-UNEL 35394; LVD 2014/35/EU
-
InternationalEU Directive 2011/65/EU (RoHS)
Use and installation methods
Suitable for the transport of power in the industry, construction sites and housing. For static use outdoor and indoor, in brickwork, metal structures, gangways, pipes, ducts or similar closed systems. Allowed for underground laying also unprotected.
Reference Construction Products Regulation 305/2011 EU and Standard EN 50575:
Given its properties of limiting the development of fire and heat emission, the cable is suitable for the supply of electricity in buildings and other civil engineering works.
Special features
Good resistance to grease and mineral oils. Good flexibility and behaviour at low temperatures. UV resistance.
Installation conditions
- Minimum installation temperature: 0°C
- Recommended minimum bending radius: 6 times the cable diameter
- Recommended maximum tensile stress: 50 N/mm² of the cross-section of the conductor
Construction
- Conductor: aluminum, stranded wire, class 2
- Insulation: rubber compound, G16 quality
- Sheath: PVC, R16 quality
- Colour: grey
Permissible current rating values and notes
• For underground installation, the installation depth is 0,8 m and the thermal resistivity of the soil is 1,0 K·m/W.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Marking
Made in Italy LA TRIVENETA CAVI ARG16R16 0,6/1 kV [form.] Cca-s3,d1,a3 IEMMEQU EFP [year] [traceability] [metric]
Declaration of Performance
- Declaration of Performance n° : 557115001
- Certification Date : 12/29/24
- AVCP (Assessment and Verification of Constancy of Performance) : AVCP 1+
- Notified body : 0051 - IMQ
- Declared performance : Cca-s3,d1,a3