ARG16R16-0,6/1 kV
Certifications and labels
ARG16R16-0,6/1 kV
Suitable for the transport of power in the industry, construction sites and housing. For static use outdoor and indoor, in brickwork, metal structures, gangways, pipes, ducts or similar closed systems. Allowed for underground laying also unprotected.
Read moreARG16R16-0,6/1 kV 1 x 16
Nexans ref. 557027144
- Construction type: 1 x 16
- Conductor cross-section: 16 mm²
- Conductor diameter: 4.9 mm
- Average insulation thickness: 0.7 mm
- Average sheath thickness: 1.4 mm
- Approximate weight: 150 kg/km
- Maximum outer diameter: 10.0 mm
- Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
- Perm current rating in air 30°C: 70 A
- Perm. current rating in pipe/air 30° C: 64 A
- Perm. current rating in pipe/buried 20° C: 75 A
- Permissible current rating buried/direct 20°C: 98 A
ARG16R16-0,6/1 kV 1 x 25
Nexans ref. 557029144
- Construction type: 1 x 25
- Conductor cross-section: 25 mm²
- Conductor diameter: 6.1 mm
- Average insulation thickness: 0.9 mm
- Average sheath thickness: 1.4 mm
- Approximate weight: 185 kg/km
- Maximum outer diameter: 11.7 mm
- Max. DC resistance of the conductor at 20°C: 1.2 Ohm/km
- Perm current rating in air 30°C: 102 A
- Perm. current rating in pipe/air 30° C: 88 A
- Perm. current rating in pipe/buried 20° C: 95 A
- Permissible current rating buried/direct 20°C: 119 A
ARG16R16-0,6/1 kV 1 x 35
Nexans ref. 557031144
- Construction type: 1 x 35
- Conductor cross-section: 35 mm²
- Conductor diameter: 7.1 mm
- Average insulation thickness: 0.9 mm
- Average sheath thickness: 1.4 mm
- Approximate weight: 220 kg/km
- Maximum outer diameter: 13.0 mm
- Max. DC resistance of the conductor at 20°C: 0.868 Ohm/km
- Perm current rating in air 30°C: 136 A
- Perm. current rating in pipe/air 30° C: 110 A
- Perm. current rating in pipe/buried 20° C: 115 A
- Permissible current rating buried/direct 20°C: 141 A
ARG16R16-0,6/1 kV 1 x 50
Nexans ref. 557033144
- Construction type: 1 x 50
- Conductor cross-section: 50 mm²
- Conductor diameter: 8.2 mm
- Average insulation thickness: 1.0 mm
- Average sheath thickness: 1.4 mm
- Approximate weight: 280 kg/km
- Maximum outer diameter: 14.7 mm
- Max. DC resistance of the conductor at 20°C: 0.641 Ohm/km
- Perm current rating in air 30°C: 164 A
- Perm. current rating in pipe/air 30° C: 131 A
- Perm. current rating in pipe/buried 20° C: 134 A
- Permissible current rating buried/direct 20°C: 167 A
ARG16R16-0,6/1 kV 1 x 70
Nexans ref. 557035144
- Construction type: 1 x 70
- Conductor cross-section: 70 mm²
- Conductor diameter: 9.9 mm
- Average insulation thickness: 1.1 mm
- Average sheath thickness: 1.4 mm
- Approximate weight: 320 kg/km
- Maximum outer diameter: 16.6 mm
- Max. DC resistance of the conductor at 20°C: 0.443 Ohm/km
- Perm current rating in air 30°C: 218 A
- Perm. current rating in pipe/air 30° C: 175 A
- Perm. current rating in pipe/buried 20° C: 173 A
- Permissible current rating buried/direct 20°C: 204 A
ARG16R16-0,6/1 kV 1 x 95
Nexans ref. 557037144
- Construction type: 1 x 95
- Conductor cross-section: 95 mm²
- Conductor diameter: 11.4 mm
- Average insulation thickness: 1.1 mm
- Average sheath thickness: 1.5 mm
- Approximate weight: 460 kg/km
- Maximum outer diameter: 18.6 mm
- Max. DC resistance of the conductor at 20°C: 0.32 Ohm/km
- Perm current rating in air 30°C: 261 A
- Perm. current rating in pipe/air 30° C: 209 A
- Perm. current rating in pipe/buried 20° C: 196 A
- Permissible current rating buried/direct 20°C: 245 A
ARG16R16-0,6/1 kV 1 x 120
Nexans ref. 557039144
- Construction type: 1 x 120
- Conductor cross-section: 120 mm²
- Conductor diameter: 13.1 mm
- Average insulation thickness: 1.2 mm
- Average sheath thickness: 1.5 mm
- Approximate weight: 570 kg/km
- Maximum outer diameter: 20.5 mm
- Max. DC resistance of the conductor at 20°C: 0.253 Ohm/km
- Perm current rating in air 30°C: 310 A
- Perm. current rating in pipe/air 30° C: 250 A
- Perm. current rating in pipe/buried 20° C: 238 A
- Permissible current rating buried/direct 20°C: 277 A
ARG16R16-0,6/1 kV 1 x 150
Nexans ref. 557041144
- Construction type: 1 x 150
- Conductor cross-section: 150 mm²
- Conductor diameter: 14.4 mm
- Average insulation thickness: 1.4 mm
- Average sheath thickness: 1.6 mm
- Approximate weight: 670 kg/km
- Maximum outer diameter: 22.8 mm
- Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
- Perm current rating in air 30°C: 350 A
- Perm. current rating in pipe/air 30° C: 280 A
- Perm. current rating in pipe/buried 20° C: 250 A
- Permissible current rating buried/direct 20°C: 313 A
ARG16R16-0,6/1 kV 1 x 185
Nexans ref. 557043144
- Construction type: 1 x 185
- Conductor cross-section: 185 mm²
- Conductor diameter: 16.2 mm
- Average insulation thickness: 1.6 mm
- Average sheath thickness: 1.6 mm
- Approximate weight: 810 kg/km
- Maximum outer diameter: 25.0 mm
- Max. DC resistance of the conductor at 20°C: 0.164 Ohm/km
- Perm current rating in air 30°C: 415 A
- Perm. current rating in pipe/air 30° C: 334 A
- Perm. current rating in pipe/buried 20° C: 300 A
- Permissible current rating buried/direct 20°C: 350 A
ARG16R16-0,6/1 kV 1 x 240
Nexans ref. 557045144
- Construction type: 1 x 240
- Conductor cross-section: 240 mm²
- Conductor diameter: 18.4 mm
- Average insulation thickness: 1.7 mm
- Average sheath thickness: 1.7 mm
- Approximate weight: 1025 kg/km
- Maximum outer diameter: 27.9 mm
- Max. DC resistance of the conductor at 20°C: 0.125 Ohm/km
- Perm current rating in air 30°C: 490 A
- Perm. current rating in pipe/air 30° C: 392 A
- Perm. current rating in pipe/buried 20° C: 331 A
- Permissible current rating buried/direct 20°C: 413 A
ARG16R16-0,6/1 kV 1 x 300
Nexans ref. 557047144
- Construction type: 1 x 300
- Conductor cross-section: 300 mm²
- Conductor diameter: 20.65 mm
- Average insulation thickness: 1.8 mm
- Average sheath thickness: 1.8 mm
- Approximate weight: 1205 kg/km
- Maximum outer diameter: 30.7 mm
- Max. DC resistance of the conductor at 20°C: 0.1 Ohm/km
- Perm current rating in air 30°C: 567 A
- Perm. current rating in pipe/air 30° C: - A
- Perm. current rating in pipe/buried 20° C: 400 A
- Permissible current rating buried/direct 20°C: 454 A
ARG16R16-0,6/1 kV 1 x 400
Nexans ref. 557049144
- Construction type: 1 x 400
- Conductor cross-section: 400 mm²
- Conductor diameter: 23.6 mm
- Average insulation thickness: 2.0 mm
- Average sheath thickness: 1.9 mm
- Approximate weight: 1660 kg/km
- Maximum outer diameter: 35.0 mm
- Max. DC resistance of the conductor at 20°C: 0.078 Ohm/km
- Perm current rating in air 30°C: 665 A
- Perm. current rating in pipe/air 30° C: - A
- Perm. current rating in pipe/buried 20° C: 450 A
- Permissible current rating buried/direct 20°C: 512 A
ARG16R16-0,6/1 kV 1 x 500
Nexans ref. 557051144
- Construction type: 1 x 500
- Conductor cross-section: 500 mm²
- Conductor diameter: 26.5 mm
- Average insulation thickness: 2.2 mm
- Average sheath thickness: 2.0 mm
- Approximate weight: 1940 kg/km
- Maximum outer diameter: 38.6 mm
- Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
- Perm current rating in air 30°C: 765 A
- Perm. current rating in pipe/air 30° C: - A
- Perm. current rating in pipe/buried 20° C: 505 A
- Permissible current rating buried/direct 20°C: 578 A
ARG16R16-0,6/1 kV 1 x 630
Nexans ref. 557052144
- Construction type: 1 x 630
- Conductor cross-section: 630 mm²
- Conductor diameter: 30.2 mm
- Average insulation thickness: 2.4 mm
- Average sheath thickness: 2.2 mm
- Approximate weight: 2460 kg/km
- Maximum outer diameter: 43.1 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Perm current rating in air 30°C: 880 A
- Perm. current rating in pipe/air 30° C: - A
- Perm. current rating in pipe/buried 20° C: 580 A
- Permissible current rating buried/direct 20°C: 646 A
Description
Description
Standards
-
ProductCEI 20-13; CEI-UNEL 35394; LVD 2014/35/EU
-
InternationalEU Directive 2011/65/EU (RoHS)
Use and installation methods
Suitable for the transport of power in the industry, construction sites and housing. For static use outdoor and indoor, in brickwork, metal structures, gangways, pipes, ducts or similar closed systems. Allowed for underground laying also unprotected.
Reference Construction Products Regulation 305/2011 EU and Standard EN 50575:
Given its properties of limiting the development of fire and heat emission, the cable is suitable for the supply of electricity in buildings and other civil engineering works.
Special features
Good resistance to grease and mineral oils. Good flexibility and behaviour at low temperatures. UV resistance.
Installation conditions
- Minimum installation temperature: 0°C
- Recommended minimum bending radius: 6 times the cable diameter
- Recommended maximum tensile stress: 50 N/mm² of the cross-section of the conductor
Construction
- Conductor: aluminum, stranded wire, class 2
- Insulation: rubber compound, G16 quality
- Sheath: PVC, R16 quality
- Colour: grey
Permissible current rating values and notes
• For underground installation, the installation depth is 0,8 m and the thermal resistivity of the soil is 1,0 K·m/W.
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Marking
Made in Italy LA TRIVENETA CAVI ARG16R16 0,6/1 kV [form.] Cca-s3,d1,a3 IEMMEQU EFP [year] [traceability] [metric]
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania