TRIFLEX H07RN-F

Products

TRIFLEX H07RN-F 1 x 1.5

Nexans ref. 602017101

  • Construction type: 1 x 1,5
  • With Green/Yellow core: No
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 1
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 7.1 mm
  • Sheath thickness: 1.4 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 16 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 23 A
  • Voltage Drop: 26.5 V/A.km

 

TRIFLEX H07RN-F 1 x 10

Nexans ref. 602025101

  • Construction type: 1 x 10
  • With Green/Yellow core: No
  • Conductor cross-section: 10 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 4.0 mm
  • Maximum outer diameter: 11.9 mm
  • Sheath thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 53 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 76 A
  • Voltage Drop: 3.87 V/A.km

 

TRIFLEX H07RN-F 1 x 120

Nexans ref. 602039101

  • Construction type: 1 x 120
  • With Green/Yellow core: No
  • Conductor cross-section: 120 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.8 mm
  • Conductor diameter: 13.8 mm
  • Maximum outer diameter: 28.6 mm
  • Sheath thickness: 3.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.161 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 260 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 366 A
  • Voltage Drop: 0.39 V/A.km

 

TRIFLEX H07RN-F 1 x 150

Nexans ref. 602041101

  • Construction type: 1 x 150
  • With Green/Yellow core: No
  • Conductor cross-section: 150 mm²
  • Number of cores: 1
  • Average insulation thickness: 2.0 mm
  • Conductor diameter: 15.4 mm
  • Maximum outer diameter: 31.4 mm
  • Sheath thickness: 3.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 300 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 425 A
  • Voltage Drop: 0.33 V/A.km

 

TRIFLEX H07RN-F 1 x 16

Nexans ref. 602027101

  • Construction type: 1 x 16
  • With Green/Yellow core: No
  • Conductor cross-section: 16 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 5.0 mm
  • Maximum outer diameter: 13.4 mm
  • Sheath thickness: 1.9 mm
  • Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 71 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 102 A
  • Voltage Drop: 2.47 V/A.km

 

TRIFLEX H07RN-F 1 x 185

Nexans ref. 602043101

  • Construction type: 1 x 185
  • With Green/Yellow core: No
  • Conductor cross-section: 185 mm²
  • Number of cores: 1
  • Average insulation thickness: 2.2 mm
  • Conductor diameter: 16.9 mm
  • Maximum outer diameter: 34.4 mm
  • Sheath thickness: 3.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.106 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 341 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 488 A
  • Voltage Drop: 0.28 V/A.km

 

TRIFLEX H07RN-F 1 x 2.5

Nexans ref. 602019101

  • Construction type: 1 x 2,5
  • With Green/Yellow core: No
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 1
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 7.9 mm
  • Sheath thickness: 1.4 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 20 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 31 A
  • Voltage Drop: 16.0 V/A.km

 

TRIFLEX H07RN-F 1 x 240

Nexans ref. 602045101

  • Construction type: 1 x 240
  • With Green/Yellow core: No
  • Conductor cross-section: 240 mm²
  • Number of cores: 1
  • Average insulation thickness: 2.4 mm
  • Conductor diameter: 19.5 mm
  • Maximum outer diameter: 38.3 mm
  • Sheath thickness: 3.5 mm
  • Max. DC resistance of the conductor at 20°C: 0.08 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 407 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 581 A
  • Voltage Drop: 0.22 V/A.km

 

TRIFLEX H07RN-F 1 x 25

Nexans ref. 602029101

  • Construction type: 1 x 25
  • With Green/Yellow core: No
  • Conductor cross-section: 25 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 6.2 mm
  • Maximum outer diameter: 15.8 mm
  • Sheath thickness: 2.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.78 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 94 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 129 A
  • Voltage Drop: 1.61 V/A.km

 

TRIFLEX H07RN-F 1 x 300

Nexans ref. 602047101

  • Construction type: 1 x 300
  • With Green/Yellow core: No
  • Conductor cross-section: 300 mm²
  • Number of cores: 1
  • Average insulation thickness: 2.6 mm
  • Conductor diameter: 21.6 mm
  • Maximum outer diameter: 41.9 mm
  • Sheath thickness: 3.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.064 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 468 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 673 A
  • Voltage Drop: 0.18 V/A.km

 

TRIFLEX H07RN-F 1 x 35

Nexans ref. 602031101

  • Construction type: 1 x 35
  • With Green/Yellow core: No
  • Conductor cross-section: 35 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 7.4 mm
  • Maximum outer diameter: 17.9 mm
  • Sheath thickness: 2.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.554 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 117 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 161 A
  • Voltage Drop: 1.17 V/A.km

 

TRIFLEX H07RN-F 1 x 4

Nexans ref. 602021101

  • Construction type: 1 x 4
  • With Green/Yellow core: No
  • Conductor cross-section: 4 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 2.5 mm
  • Maximum outer diameter: 9.0 mm
  • Sheath thickness: 1.5 mm
  • Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 30 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 43 A
  • Voltage Drop: 9.93 V/A.km

 

TRIFLEX H07RN-F 1 x 400

Nexans ref. 602049101

  • Construction type: 1 x 400
  • With Green/Yellow core: No
  • Conductor cross-section: 400 mm²
  • Number of cores: 1
  • Average insulation thickness: 2.8 mm
  • Conductor diameter: 24.8 mm
  • Maximum outer diameter: 46.8 mm
  • Sheath thickness: 3.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.049 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 553 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 787 A
  • Voltage Drop: 0.16 V/A.km

 

TRIFLEX H07RN-F 1 x 50

Nexans ref. 602033101

  • Construction type: 1 x 50
  • With Green/Yellow core: No
  • Conductor cross-section: 50 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.6 mm
  • Conductor diameter: 8.9 mm
  • Maximum outer diameter: 20.6 mm
  • Sheath thickness: 2.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.386 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 148 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 198 A
  • Voltage Drop: 0.84 V/A.km

 

TRIFLEX H07RN-F 1 x 500

Nexans ref. 602051101

  • Construction type: 1 x 500
  • With Green/Yellow core: No
  • Conductor cross-section: 500 mm²
  • Number of cores: 1
  • Average insulation thickness: 3.0 mm
  • Conductor diameter: 28.5 mm
  • Maximum outer diameter: 52.0 mm
  • Sheath thickness: 4.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.038 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 620 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 905 A
  • Voltage Drop: 0.14 V/A.km

 

TRIFLEX H07RN-F 1 x 6

Nexans ref. 602023101

  • Construction type: 1 x 6
  • With Green/Yellow core: No
  • Conductor cross-section: 6 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 3.0 mm
  • Maximum outer diameter: 9.8 mm
  • Sheath thickness: 1.6 mm
  • Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 38 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 55 A
  • Voltage Drop: 6.63 V/A.km

 

TRIFLEX H07RN-F 1 x 630

Nexans ref. 602052101

  • Construction type: 1 x 630
  • With Green/Yellow core: No
  • Conductor cross-section: 630 mm²
  • Number of cores: 1
  • Average insulation thickness: 3.0 mm
  • Conductor diameter: 32.8 mm
  • Maximum outer diameter: 57.0 mm
  • Sheath thickness: 4.1 mm
  • Max. DC resistance of the conductor at 20°C: 0.029 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 742 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 1041 A
  • Voltage Drop: 0.12 V/A.km

 

TRIFLEX H07RN-F 1 x 70

Nexans ref. 602035101

  • Construction type: 1 x 70
  • With Green/Yellow core: No
  • Conductor cross-section: 70 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.6 mm
  • Conductor diameter: 10.5 mm
  • Maximum outer diameter: 23.3 mm
  • Sheath thickness: 2.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.272 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 185 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 256 A
  • Voltage Drop: 0.61 V/A.km

 

TRIFLEX H07RN-F 1 x 95

Nexans ref. 602037101

  • Construction type: 1 x 95
  • With Green/Yellow core: No
  • Conductor cross-section: 95 mm²
  • Number of cores: 1
  • Average insulation thickness: 1.8 mm
  • Conductor diameter: 12.2 mm
  • Maximum outer diameter: 26.0 mm
  • Sheath thickness: 2.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 222 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 314 A
  • Voltage Drop: 0.48 V/A.km

 

TRIFLEX H07RN-F 12G1.5

Nexans ref. 602373001

  • Construction type: 12G1,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 12
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 22.4 mm
  • Sheath thickness: 2.9 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 9 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 14 A
  • Voltage Drop: 30.7 V/A.km

 

TRIFLEX H07RN-F 12G2.5

Nexans ref. 602375001

  • Construction type: 12G2,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 12
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 26.2 mm
  • Sheath thickness: 3.1 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 12 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 16 A
  • Voltage Drop: 18.4 V/A.km

 

TRIFLEX H07RN-F 19G1.5

Nexans ref. 602469001

  • Construction type: 19G1,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 19
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 26.3 mm
  • Sheath thickness: 3.2 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 8 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 13 A
  • Voltage Drop: 30.7 V/A.km

 

TRIFLEX H07RN-F 19G2.5

Nexans ref. 602471001

  • Construction type: 19G2,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 19
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 30.9 mm
  • Sheath thickness: 3.5 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 10 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 14 A
  • Voltage Drop: 18.4 V/A.km

 

TRIFLEX H07RN-F 2 x 1

Nexans ref. 602067101

  • Construction type: 2 x 1
  • With Green/Yellow core: No
  • Conductor cross-section: 1 mm²
  • Number of cores: 2
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.3 mm
  • Maximum outer diameter: 10.0 mm
  • Sheath thickness: 1.3 mm
  • Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 10 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 18 A
  • Voltage Drop: 45.2 V/A.km

 

TRIFLEX H07RN-F 2 x 1.5

Nexans ref. 602069101

  • Construction type: 2 x 1.5
  • With Green/Yellow core: No
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 2
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 11.0 mm
  • Sheath thickness: 1.5 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 18 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 23 A
  • Voltage Drop: 30.6 V/A.km

 

TRIFLEX H07RN-F 2 x 10

Nexans ref. 602077101

  • Construction type: 2 x 10
  • With Green/Yellow core: No
  • Conductor cross-section: 10 mm²
  • Number of cores: 2
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 4.0 mm
  • Maximum outer diameter: 22.6 mm
  • Sheath thickness: 3.1 mm
  • Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 60 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 77 A
  • Voltage Drop: 4.44 V/A.km

 

TRIFLEX H07RN-F 2 x 16

Nexans ref. 602079101

  • Construction type: 2 x 16
  • With Green/Yellow core: No
  • Conductor cross-section: 16 mm²
  • Number of cores: 2
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 5.0 mm
  • Maximum outer diameter: 25.7 mm
  • Sheath thickness: 3.3 mm
  • Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 79 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 102 A
  • Voltage Drop: 2.84 V/A.km

 

TRIFLEX H07RN-F 2 x 2.5

Nexans ref. 602071101

  • Construction type: 2 x 2.5
  • With Green/Yellow core: No
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 2
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 13.1 mm
  • Sheath thickness: 1.7 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 27 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 32 A
  • Voltage Drop: 18.4 V/A.km

 

TRIFLEX H07RN-F 2 x 25

Nexans ref. 602081101

  • Construction type: 2 x 25
  • With Green/Yellow core: No
  • Conductor cross-section: 25 mm²
  • Number of cores: 2
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 6.2 mm
  • Maximum outer diameter: 30.7 mm
  • Sheath thickness: 3.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.78 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 105 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 136 A
  • Voltage Drop: 1.85 V/A.km

 

TRIFLEX H07RN-F 2 x 35

Nexans ref. 602083101

  • Construction type: 2 x 35
  • With Green/Yellow core: No
  • Conductor cross-section: 35 mm²
  • Number of cores: 2
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 7.3 mm
  • Maximum outer diameter: 34.3 mm
  • Sheath thickness: 3.7 mm
  • Max. DC resistance of the conductor at 20°C: 0.554 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 129 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 168 A
  • Voltage Drop: 1.34 V/A.km

 

TRIFLEX H07RN-F 2 x 4

Nexans ref. 602073101

  • Construction type: 2 x 4
  • With Green/Yellow core: No
  • Conductor cross-section: 4 mm²
  • Number of cores: 2
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 2.5 mm
  • Maximum outer diameter: 15.1 mm
  • Sheath thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 34 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 43 A
  • Voltage Drop: 11.4 V/A.km

 

TRIFLEX H07RN-F 2 x 6

Nexans ref. 602075101

  • Construction type: 2 x 6
  • With Green/Yellow core: No
  • Conductor cross-section: 6 mm²
  • Number of cores: 2
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 3.0 mm
  • Maximum outer diameter: 16.8 mm
  • Sheath thickness: 2.0 mm
  • Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 43 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 56 A
  • Voltage Drop: 7.63 V/A.km

 

TRIFLEX H07RN-F 24G1.5

Nexans ref. 602517001

  • Construction type: 24G1,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 24
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 30.7 mm
  • Sheath thickness: 3.5 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 7 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 12 A
  • Voltage Drop: 30.7 V/A.km

 

TRIFLEX H07RN-F 24G2.5

Nexans ref. 602519001

  • Construction type: 24G2,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 24
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 36.4 mm
  • Sheath thickness: 3.9 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 9 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 13 A
  • Voltage Drop: 18.4 V/A.km

 

TRIFLEX H07RN-F 27G2.5

Nexans ref. 602567001

  • Construction type: 27G2,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 27
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 37.1 mm
  • Sheath thickness: 4.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 7 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 11 A
  • Voltage Drop: 18.4 V/A.km

 

TRIFLEX H07RN-F 36G1.5

Nexans ref. 602636001

  • Construction type: 36G1,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 36
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 35.2 mm
  • Sheath thickness: 3.8 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 5 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 10 A
  • Voltage Drop: 30.7 V/A.km

 

TRIFLEX H07RN-F 36G2.5

Nexans ref. 602638001

  • Construction type: 36G2,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 36
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 41.8 mm
  • Sheath thickness: 4.3 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 7 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 11 A
  • Voltage Drop: 18.4 V/A.km

 

TRIFLEX H07RN-F 3G1

Nexans ref. 602119001

  • Construction type: 3G1
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1 mm²
  • Number of cores: 3
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.3 mm
  • Maximum outer diameter: 10.7 mm
  • Sheath thickness: 1.4 mm
  • Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 10 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 18 A
  • Voltage Drop: 45.2 V/A.km

 

TRIFLEX H07RN-F 3G1.5

Nexans ref. 602121001

  • Construction type: 3G1,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 3
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 11.9 mm
  • Sheath thickness: 1.6 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 16 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 23 A
  • Voltage Drop: 30.6 V/A.km

 

TRIFLEX H07RN-F 3G10

Nexans ref. 602129001

  • Construction type: 3G10
  • With Green/Yellow core: Yes
  • Conductor cross-section: 10 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 4.0 mm
  • Maximum outer diameter: 24.2 mm
  • Sheath thickness: 3.3 mm
  • Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 51 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 77 A
  • Voltage Drop: 4.44 V/A.km

 

TRIFLEX H07RN-F 3G120

Nexans ref. 602143001

  • Construction type: 3G120
  • With Green/Yellow core: Yes
  • Conductor cross-section: 120 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.8 mm
  • Conductor diameter: 13.8 mm
  • Maximum outer diameter: 60.0 mm
  • Sheath thickness: 5.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.161 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 238 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 363 A
  • Voltage Drop: 0.44 V/A.km

 

TRIFLEX H07RN-F 3G150

Nexans ref. 602145001

  • Construction type: 3G150
  • With Green/Yellow core: Yes
  • Conductor cross-section: 150 mm²
  • Number of cores: 3
  • Average insulation thickness: 2.0 mm
  • Conductor diameter: 15.4 mm
  • Maximum outer diameter: 66.0 mm
  • Sheath thickness: 6.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 273 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 416 A
  • Voltage Drop: 0.37 V/A.km

 

TRIFLEX H07RN-F 3G16

Nexans ref. 602131001

  • Construction type: 3G16
  • With Green/Yellow core: Yes
  • Conductor cross-section: 16 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 5.0 mm
  • Maximum outer diameter: 27.6 mm
  • Sheath thickness: 3.5 mm
  • Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 67 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 102 A
  • Voltage Drop: 2.84 V/A.km

 

TRIFLEX H07RN-F 3G185

Nexans ref. 602147001

  • Construction type: 3G185
  • With Green/Yellow core: Yes
  • Conductor cross-section: 185 mm²
  • Number of cores: 3
  • Average insulation thickness: 2.2 mm
  • Conductor diameter: 16.9 mm
  • Maximum outer diameter: 72.0 mm
  • Sheath thickness: 6.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.106 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 309 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 475 A
  • Voltage Drop: 0.22 V/A.km

 

TRIFLEX H07RN-F 3G2.5

Nexans ref. 602123001

  • Construction type: 3G2,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 3
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 14.0 mm
  • Sheath thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 25 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 32 A
  • Voltage Drop: 18.4 V/A.km

 

TRIFLEX H07RN-F 3G240

Nexans ref. 602149001

  • Construction type: 3G240
  • With Green/Yellow core: Yes
  • Conductor cross-section: 240 mm²
  • Number of cores: 3
  • Average insulation thickness: 2.4 mm
  • Conductor diameter: 19.5 mm
  • Maximum outer diameter: 82.0 mm
  • Sheath thickness: 7.1 mm
  • Max. DC resistance of the conductor at 20°C: 0.08 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 365 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 559 A
  • Voltage Drop: 0.21 V/A.km

 

TRIFLEX H07RN-F 3G25

Nexans ref. 602133001

  • Construction type: 3G25
  • With Green/Yellow core: Yes
  • Conductor cross-section: 25 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 6.2 mm
  • Maximum outer diameter: 33.0 mm
  • Sheath thickness: 3.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.78 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 89 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 136 A
  • Voltage Drop: 1.85 V/A.km

 

TRIFLEX H07RN-F 3G300

Nexans ref. 602151001

  • Construction type: 3G300
  • With Green/Yellow core: Yes
  • Conductor cross-section: 300 mm²
  • Number of cores: 3
  • Average insulation thickness: 2.6 mm
  • Conductor diameter: 21.6 mm
  • Maximum outer diameter: 90.0 mm
  • Sheath thickness: 7.7 mm
  • Max. DC resistance of the conductor at 20°C: 0.064 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 450 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 637 A
  • Voltage Drop: 0.18 V/A.km

 

TRIFLEX H07RN-F 3G35

Nexans ref. 602135001

  • Construction type: 3G35
  • With Green/Yellow core: Yes
  • Conductor cross-section: 35 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 7.4 mm
  • Maximum outer diameter: 37.1 mm
  • Sheath thickness: 4.1 mm
  • Max. DC resistance of the conductor at 20°C: 0.554 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 110 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 168 A
  • Voltage Drop: 1.34 V/A.km

 

TRIFLEX H07RN-F 3G4

Nexans ref. 602125001

  • Construction type: 3G4
  • With Green/Yellow core: Yes
  • Conductor cross-section: 4 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 2.5 mm
  • Maximum outer diameter: 16.2 mm
  • Sheath thickness: 1.9 mm
  • Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 29 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 43 A
  • Voltage Drop: 11.4 V/A.km

 

TRIFLEX H07RN-F 3G50

Nexans ref. 602137001

  • Construction type: 3G50
  • With Green/Yellow core: Yes
  • Conductor cross-section: 50 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.6 mm
  • Conductor diameter: 8.9 mm
  • Maximum outer diameter: 42.9 mm
  • Sheath thickness: 4.5 mm
  • Max. DC resistance of the conductor at 20°C: 0.386 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 138 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 203 A
  • Voltage Drop: 0.96 V/A.km

 

TRIFLEX H07RN-F 3G6

Nexans ref. 602127001

  • Construction type: 3G6
  • With Green/Yellow core: Yes
  • Conductor cross-section: 6 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 3.0 mm
  • Maximum outer diameter: 18.0 mm
  • Sheath thickness: 2.1 mm
  • Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 36 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 56 A
  • Voltage Drop: 7.63 V/A.km

 

TRIFLEX H07RN-F 3G70

Nexans ref. 602139001

  • Construction type: 3G70
  • With Green/Yellow core: Yes
  • Conductor cross-section: 70 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.6 mm
  • Conductor diameter: 10.5 mm
  • Maximum outer diameter: 48.3 mm
  • Sheath thickness: 4.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.272 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 172 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 254 A
  • Voltage Drop: 0.69 V/A.km

 

TRIFLEX H07RN-F 3G95

Nexans ref. 602141001

  • Construction type: 3G95
  • With Green/Yellow core: Yes
  • Conductor cross-section: 95 mm²
  • Number of cores: 3
  • Average insulation thickness: 1.8 mm
  • Conductor diameter: 12.2 mm
  • Maximum outer diameter: 54.0 mm
  • Sheath thickness: 5.3 mm
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 204 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 299 A
  • Voltage Drop: 0.55 V/A.km

 

TRIFLEX H07RN-F 4G1

Nexans ref. 602171001

  • Construction type: 4G1
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1 mm²
  • Number of cores: 4
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.3 mm
  • Maximum outer diameter: 11.9 mm
  • Sheath thickness: 1.5 mm
  • Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 10 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 16 A
  • Voltage Drop: 39.0 V/A.km

 

TRIFLEX H07RN-F 4G1.5

Nexans ref. 602173001

  • Construction type: 4G1.5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 4
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 13.1 mm
  • Sheath thickness: 1.7 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 16 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 21 A
  • Voltage Drop: 26.5 V/A.km

 

TRIFLEX H07RN-F 4G10

Nexans ref. 602181001

  • Construction type: 4G10
  • With Green/Yellow core: Yes
  • Conductor cross-section: 10 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 4.0 mm
  • Maximum outer diameter: 26.5 mm
  • Sheath thickness: 3.4 mm
  • Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 52 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 68 A
  • Voltage Drop: 3.87 V/A.km

 

TRIFLEX H07RN-F 4G120

Nexans ref. 602195001

  • Construction type: 4G120
  • With Green/Yellow core: Yes
  • Conductor cross-section: 120 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.8 mm
  • Conductor diameter: 13.8 mm
  • Maximum outer diameter: 66.0 mm
  • Sheath thickness: 6.0 mm
  • Max. DC resistance of the conductor at 20°C: 0.161 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 246 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 325 A
  • Voltage Drop: 0.39 V/A.km

 

TRIFLEX H07RN-F 4G150

Nexans ref. 602197001

  • Construction type: 4G150
  • With Green/Yellow core: Yes
  • Conductor cross-section: 150 mm²
  • Number of cores: 4
  • Average insulation thickness: 2.0 mm
  • Conductor diameter: 15.4 mm
  • Maximum outer diameter: 73.0 mm
  • Sheath thickness: 6.5 mm
  • Max. DC resistance of the conductor at 20°C: 0.129 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 282 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 373 A
  • Voltage Drop: 0.33 V/A.km

 

TRIFLEX H07RN-F 4G16

Nexans ref. 602183001

  • Construction type: 4G16
  • With Green/Yellow core: Yes
  • Conductor cross-section: 16 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 5.0 mm
  • Maximum outer diameter: 30.1 mm
  • Sheath thickness: 3.6 mm
  • Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 69 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 92 A
  • Voltage Drop: 2.47 V/A.km

 

TRIFLEX H07RN-F 4G185

Nexans ref. 602199001

  • Construction type: 4G185
  • With Green/Yellow core: Yes
  • Conductor cross-section: 185 mm²
  • Number of cores: 4
  • Average insulation thickness: 2.2 mm
  • Conductor diameter: 16.9 mm
  • Maximum outer diameter: 80.0 mm
  • Sheath thickness: 4.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.106 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 319 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 425 A
  • Voltage Drop: 0.28 V/A.km

 

TRIFLEX H07RN-F 4G2.5

Nexans ref. 602175001

  • Construction type: 4G2.5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 4
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 15.5 mm
  • Sheath thickness: 1.9 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 20 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 29 A
  • Voltage Drop: 16.0 V/A.km

 

TRIFLEX H07RN-F 4G25

Nexans ref. 602185001

  • Construction type: 4G25
  • With Green/Yellow core: Yes
  • Conductor cross-section: 25 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 6.2 mm
  • Maximum outer diameter: 36.6 mm
  • Sheath thickness: 4.1 mm
  • Max. DC resistance of the conductor at 20°C: 0.78 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 92 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 122 A
  • Voltage Drop: 1.61 V/A.km

 

TRIFLEX H07RN-F 4G35

Nexans ref. 602187001

  • Construction type: 4G35
  • With Green/Yellow core: Yes
  • Conductor cross-section: 35 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 7.4 mm
  • Maximum outer diameter: 41.1 mm
  • Sheath thickness: 4.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.554 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 114 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 150 A
  • Voltage Drop: 1.17 V/A.km

 

TRIFLEX H07RN-F 4G4

Nexans ref. 602177001

  • Construction type: 4G4
  • With Green/Yellow core: Yes
  • Conductor cross-section: 4 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 2.5 mm
  • Maximum outer diameter: 17.9 mm
  • Sheath thickness: 2.0 mm
  • Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 30 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 38 A
  • Voltage Drop: 9.93 V/A.km

 

TRIFLEX H07RN-F 4G50

Nexans ref. 602189001

  • Construction type: 4G50
  • With Green/Yellow core: Yes
  • Conductor cross-section: 50 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.6 mm
  • Conductor diameter: 8.9 mm
  • Maximum outer diameter: 47.5 mm
  • Sheath thickness: 4.8 mm
  • Max. DC resistance of the conductor at 20°C: 0.386 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 143 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 182 A
  • Voltage Drop: 0.84 V/A.km

 

TRIFLEX H07RN-F 4G6

Nexans ref. 602179001

  • Construction type: 4G6
  • With Green/Yellow core: Yes
  • Conductor cross-section: 6 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 3.0 mm
  • Maximum outer diameter: 20.0 mm
  • Sheath thickness: 2.3 mm
  • Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 37 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 50 A
  • Voltage Drop: 6.63 V/A.km

 

TRIFLEX H07RN-F 4G70

Nexans ref. 602191001

  • Construction type: 4G70
  • With Green/Yellow core: Yes
  • Conductor cross-section: 70 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.6 mm
  • Conductor diameter: 10.5 mm
  • Maximum outer diameter: 54.0 mm
  • Sheath thickness: 5.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.272 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 178 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 232 A
  • Voltage Drop: 0.61 V/A.km

 

TRIFLEX H07RN-F 4G95

Nexans ref. 602193001

  • Construction type: 4G95
  • With Green/Yellow core: Yes
  • Conductor cross-section: 95 mm²
  • Number of cores: 4
  • Average insulation thickness: 1.8 mm
  • Conductor diameter: 12.2 mm
  • Maximum outer diameter: 61.0 mm
  • Sheath thickness: 5.9 mm
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 210 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 281 A
  • Voltage Drop: 0.48 V/A.km

 

TRIFLEX H07RN-F 5G1

Nexans ref. 602223001

  • Construction type: 5G1
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1 mm²
  • Number of cores: 5
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.3 mm
  • Maximum outer diameter: 13.1 mm
  • Sheath thickness: 1.6 mm
  • Max. DC resistance of the conductor at 20°C: 19.5 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 10 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 16 A
  • Voltage Drop: 39.0 V/A.km

 

TRIFLEX H07RN-F 5G1.5

Nexans ref. 602225001

  • Construction type: 5G1,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 5
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 14.4 mm
  • Sheath thickness: 1.8 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 16 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 21 A
  • Voltage Drop: 26.5 V/A.km

 

TRIFLEX H07RN-F 5G10

Nexans ref. 602233001

  • Construction type: 5G10
  • With Green/Yellow core: Yes
  • Conductor cross-section: 10 mm²
  • Number of cores: 5
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 4.0 mm
  • Maximum outer diameter: 29.1 mm
  • Sheath thickness: 3.6 mm
  • Max. DC resistance of the conductor at 20°C: 1.91 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 54 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 68 A
  • Voltage Drop: 3.87 V/A.km

 

TRIFLEX H07RN-F 5G16

Nexans ref. 602235001

  • Construction type: 5G16
  • With Green/Yellow core: Yes
  • Conductor cross-section: 16 mm²
  • Number of cores: 5
  • Average insulation thickness: 1.2 mm
  • Conductor diameter: 5.0 mm
  • Maximum outer diameter: 33.3 mm
  • Sheath thickness: 3.9 mm
  • Max. DC resistance of the conductor at 20°C: 1.21 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 71 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 92 A
  • Voltage Drop: 2.47 V/A.km

 

TRIFLEX H07RN-F 5G2.5

Nexans ref. 602227001

  • Construction type: 5G2,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 5
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 17.0 mm
  • Sheath thickness: 2.0 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 20 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 29 A
  • Voltage Drop: 16.0 V/A.km

 

TRIFLEX H07RN-F 5G25

Nexans ref. 602237001

  • Construction type: 5G25
  • With Green/Yellow core: Yes
  • Conductor cross-section: 25 mm²
  • Number of cores: 5
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 6.2 mm
  • Maximum outer diameter: 40.4 mm
  • Sheath thickness: 4.4 mm
  • Max. DC resistance of the conductor at 20°C: 0.78 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 94 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 122 A
  • Voltage Drop: 1.61 V/A.km

 

TRIFLEX H07RN-F 5G35

Nexans ref. 602239201

  • Construction type: 5G35
  • With Green/Yellow core: Yes
  • Conductor cross-section: 35 mm²
  • Number of cores: 5
  • Average insulation thickness: 1.4 mm
  • Conductor diameter: 7.4 mm
  • Maximum outer diameter: 45.1 mm
  • Sheath thickness: 4.6 mm
  • Max. DC resistance of the conductor at 20°C: 0.554 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 114 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 150 A
  • Voltage Drop: 1.17 V/A.km

 

TRIFLEX H07RN-F 5G4

Nexans ref. 602229001

  • Construction type: 5G4
  • With Green/Yellow core: Yes
  • Conductor cross-section: 4 mm²
  • Number of cores: 5
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 2.5 mm
  • Maximum outer diameter: 19.9 mm
  • Sheath thickness: 2.2 mm
  • Max. DC resistance of the conductor at 20°C: 4.95 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 30 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 38 A
  • Voltage Drop: 9.93 V/A.km

 

TRIFLEX H07RN-F 5G50

Nexans ref. 602241201

  • Construction type: 5G50
  • With Green/Yellow core: Yes
  • Conductor cross-section: 50 mm²
  • Number of cores: 5
  • Average insulation thickness: 1.6 mm
  • Conductor diameter: 8.9 mm
  • Maximum outer diameter: 53.0 mm
  • Sheath thickness: 5.2 mm
  • Max. DC resistance of the conductor at 20°C: 0.386 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 143 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 182 A
  • Voltage Drop: 0.84 V/A.km

 

TRIFLEX H07RN-F 5G6

Nexans ref. 602231001

  • Construction type: 5G6
  • With Green/Yellow core: Yes
  • Conductor cross-section: 6 mm²
  • Number of cores: 5
  • Average insulation thickness: 1.0 mm
  • Conductor diameter: 3.0 mm
  • Maximum outer diameter: 22.2 mm
  • Sheath thickness: 2.5 mm
  • Max. DC resistance of the conductor at 20°C: 3.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 38 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 50 A
  • Voltage Drop: 6.63 V/A.km

 

TRIFLEX H07RN-F 5G70

Nexans ref. 602243201

  • Construction type: 5G70
  • With Green/Yellow core: Yes
  • Conductor cross-section: 70 mm²
  • Number of cores: 5
  • Average insulation thickness: 1.6 mm
  • Conductor diameter: 10.5 mm
  • Maximum outer diameter: 60.0 mm
  • Sheath thickness: 5.7 mm
  • Max. DC resistance of the conductor at 20°C: 0.272 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 178 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 232 A
  • Voltage Drop: 0.61 V/A.km

 

TRIFLEX H07RN-F 5G95

Nexans ref. 602245201

  • Construction type: 5G95
  • With Green/Yellow core: Yes
  • Conductor cross-section: 95 mm²
  • Number of cores: 5
  • Average insulation thickness: 1.8 mm
  • Conductor diameter: 12.2 mm
  • Maximum outer diameter: 67.0 mm
  • Sheath thickness: 6.3 mm
  • Max. DC resistance of the conductor at 20°C: 0.206 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 210 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 281 A
  • Voltage Drop: 0.48 V/A.km

 

TRIFLEX H07RN-F 7G1.5

Nexans ref. 602301001

  • Construction type: 7G1,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 1.5 mm²
  • Number of cores: 7
  • Average insulation thickness: 0.8 mm
  • Conductor diameter: 1.5 mm
  • Maximum outer diameter: 17.2 mm
  • Sheath thickness: 2.5 mm
  • Max. DC resistance of the conductor at 20°C: 13.3 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 11 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 16 A
  • Voltage Drop: 30.7 V/A.km

 

TRIFLEX H07RN-F 7G2.5

Nexans ref. 602303001

  • Construction type: 7G2,5
  • With Green/Yellow core: Yes
  • Conductor cross-section: 2.5 mm²
  • Number of cores: 7
  • Average insulation thickness: 0.9 mm
  • Conductor diameter: 2.0 mm
  • Maximum outer diameter: 20.0 mm
  • Sheath thickness: 2.7 mm
  • Max. DC resistance of the conductor at 20°C: 7.98 Ohm/km
  • Permissible mobile installation current in open air, ambient temperature 30 °C: 15 A
  • Protected and fixed installation current in open air, ambient temperature 30°C: 19 A
  • Voltage Drop: 18.4 V/A.km

 

Description

Description

Standards

  • Product
    EN 50525-2-21; EN 50565-1; LVD 2014/35/EU
  • International
    EU Directive 2011/65/EU (RoHS)

Use and installation methods

Reference Guide EN 50565:
For mobile laying: indoor use, outdoor use and in industrial and agricultural workshops.
For supplying industrial and agricultural machines and appliances subject to medium mechanical stresses (e.g. heating plates, inspection lamps, electric tools such as drills, circular saws and domestic electric tools). For fixed laying: it can be used in temporary buildings or huts in building sites. Suitable for connections of constructive elements of lifting appliances and machines. Suitable for use in dry, humid or moist rooms (AD6). If used in protected installations such as tubes or similar closed systems, voltages up to 1000V in a.c. or 750V in d.c. to ground are allowed.

Reference Construction Products Regulation 305/2011 EU and Standard EN 50575:
The cable is suitable for the supply of electricity in buildings and other civil engineering works.

Special features
Good flexibility and mechanical resistance to abrasion, shocks, crushing and lacerations.
Good resistance to atmospheric agents, grease and mineral oils. UV-resistant.

Installation conditions

  • Minimum installation temperature: -25°C
  • Recommended minimum bending radius: 6 times the cable diameter for mobile use, 4 times for static use
  • Recommended maximum tensile stress: 15 N/mm² of the cross-section of the copper for mobile use, 50 N/mm² for static use.

Construction

  • Conductor: class 5, flexible, plain copper wire
  • Insulation: rubber compound, EI4 quality
  • Sheath: polychloroprene or equivalent synthetic elastomer, water resistence (AD6)
  • Colour: black

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare annealed copper stranded
Conductor shape
Circular
Insulation
Rubber compound, EI4 quality
Lead free
Yes
Outer sheath
Polychloroprene or equivalent synthetic elastomer
Sheath colour
Black

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
450/750 V

Mechanical characteristics

Mechanical characteristics

Maximum tensile strength dynamic
15 N/mm2
Maximum tensile strength static
50 N/mm2

Usage characteristics

Usage characteristics

Chemical resistance
Accidental
Water proof
Good
Dynamic bending factor
6 (xD)
Maximum operating temperature
60 °C
Minimum bending radius, static (XD)
4
Minimum installation temperature
-25 °C
Minimum operating temperature
-40 °C
RoHS compliant
Yes
Short-circuit max. conductor temperature
200 °C

Resources

Resources

Documentation

Selling & delivery Information

Marking
LTC IEMMEQU ◄HAR► TRIFLEX H07RN-F [form.] Eca 450/750V - Fixed and Protected 600/1000V [order number] [year] Made in Italy (CE logo) [metric]

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close