H07BQ-F
Certifications and labels
H07BQ-F
They can be used both indoors and outdoors, in dry, damp or wet conditions. Suitable for heavy-duty uses and to power industrial and farm machinery.
Read moreH07BQ-F 2 x 1
Nexans ref. 116067109
- Core identification: Blue, brown
- Number of cores: 2
- Conductor cross-section: 1 mm²
- Conductor diameter: 1.3 mm
- Average sheath thickness: 0.9 mm
- Maximum outer diameter: 9.0 mm
- Perm current rating in air 30°C: 17 A
H07BQ-F 3G1
Nexans ref. 116119009
- Core identification: Blue, brown, green/yellow
- Number of cores: 3
- Conductor cross-section: 1 mm²
- Conductor diameter: 1.3 mm
- Average sheath thickness: 0.9 mm
- Maximum outer diameter: 9.5 mm
- Perm current rating in air 30°C: 17 A
H07BQ-F 4G1
Nexans ref. 116171009
- Core identification: Brown, black, grey, green / yellow
- Number of cores: 4
- Conductor cross-section: 1 mm²
- Conductor diameter: 1.3 mm
- Average sheath thickness: 0.9 mm
- Maximum outer diameter: 10.7 mm
- Perm current rating in air 30°C: 17 A
H07BQ-F 5G1
Nexans ref. 116223009
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Conductor cross-section: 1 mm²
- Conductor diameter: 1.3 mm
- Average sheath thickness: 1.0 mm
- Maximum outer diameter: 11.9 mm
- Perm current rating in air 30°C: 17 A
H07BQ-F 2 x 1.5
Nexans ref. 116069109
- Core identification: Blue, brown
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Average sheath thickness: 1.0 mm
- Maximum outer diameter: 9.8 mm
- Perm current rating in air 30°C: 26 A
H07BQ-F 3G1.5
Nexans ref. 116121009
- Core identification: Blue, brown, green/yellow
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Average sheath thickness: 1.0 mm
- Maximum outer diameter: 10.4 mm
- Perm current rating in air 30°C: 23 A
H07BQ-F 4G1.5
Nexans ref. 116173009
- Core identification: Brown, black, grey, green / yellow
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Average sheath thickness: 1.1 mm
- Maximum outer diameter: 11.6 mm
- Perm current rating in air 30°C: 23 A
H07BQ-F 5G1.5
Nexans ref. 116225009
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
- Conductor diameter: 1.5 mm
- Average sheath thickness: 1.1 mm
- Maximum outer diameter: 12.7 mm
- Perm current rating in air 30°C: 23 A
H07BQ-F 2 x 2.5
Nexans ref. 116071109
- Core identification: Blue, brown
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 2.0 mm
- Average sheath thickness: 1.1 mm
- Maximum outer diameter: 11.6 mm
- Perm current rating in air 30°C: 36 A
H07BQ-F 3G2.5
Nexans ref. 116123009
- Core identification: Blue, brown, green/yellow
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 2.0 mm
- Average sheath thickness: 1.1 mm
- Maximum outer diameter: 12.4 mm
- Perm current rating in air 30°C: 32 A
H07BQ-F 4G2.5
Nexans ref. 116175009
- Core identification: Brown, black, grey, green / yellow
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 2.0 mm
- Average sheath thickness: 1.2 mm
- Maximum outer diameter: 13.8 mm
- Perm current rating in air 30°C: 32 A
H07BQ-F 5G2.5
Nexans ref. 116227009
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Conductor diameter: 2.0 mm
- Average sheath thickness: 1.3 mm
- Maximum outer diameter: 15.3 mm
- Perm current rating in air 30°C: 32 A
H07BQ-F 2 x 4
Nexans ref. 116073109
- Core identification: Blue, brown
- Number of cores: 2
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.5 mm
- Average sheath thickness: 1.2 mm
- Maximum outer diameter: 13.7 mm
- Perm current rating in air 30°C: 49 A
H07BQ-F 3G4
Nexans ref. 116125009
- Core identification: Blue, brown, green/yellow
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.5 mm
- Average sheath thickness: 1.2 mm
- Maximum outer diameter: 14.5 mm
- Perm current rating in air 30°C: 42 A
H07BQ-F 4G4
Nexans ref. 116177009
- Core identification: Brown, black, grey, green / yellow
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.5 mm
- Average sheath thickness: 1.3 mm
- Maximum outer diameter: 16.2 mm
- Perm current rating in air 30°C: 42 A
H07BQ-F 5G4
Nexans ref. 116229009
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Conductor cross-section: 4 mm²
- Conductor diameter: 2.5 mm
- Average sheath thickness: 1.4 mm
- Maximum outer diameter: 17.9 mm
- Perm current rating in air 30°C: 42 A
H07BQ-F 2 x 6
Nexans ref. 116076109
- Core identification: Blue, brown
- Number of cores: 2
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Average sheath thickness: 1.3 mm
- Maximum outer diameter: 15.1 mm
- Perm current rating in air 30°C: 63 A
H07BQ-F 3G6
Nexans ref. 116128009
- Core identification: Blue, brown, green/yellow
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Average sheath thickness: 1.4 mm
- Maximum outer diameter: 16.3 mm
- Perm current rating in air 30°C: 54 A
H07BQ-F 4G6
Nexans ref. 116180009
- Core identification: Brown, black, grey, green / yellow
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Average sheath thickness: 1.5 mm
- Maximum outer diameter: 18.1 mm
- Perm current rating in air 30°C: 54 A
H07BQ-F 5G6
Nexans ref. 116232009
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Conductor diameter: 3.0 mm
- Average sheath thickness: 1.6 mm
- Maximum outer diameter: 20.0 mm
- Perm current rating in air 30°C: 54 A
H07BQ-F 2 x 10
Nexans ref. 116078109
- Core identification: Blue, brown
- Number of cores: 2
- Conductor cross-section: 10 mm²
- Conductor diameter: 4.0 mm
- Average sheath thickness: 2.0 mm
- Maximum outer diameter: 19.9 mm
- Perm current rating in air 30°C: 86 A
H07BQ-F 3G10
Nexans ref. 116130009
- Core identification: Blue, brown, green/yellow
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Conductor diameter: 4.0 mm
- Average sheath thickness: 2.1 mm
- Maximum outer diameter: 21.4 mm
- Perm current rating in air 30°C: 75 A
H07BQ-F 4G10
Nexans ref. 116182009
- Core identification: Brown, black, grey, green / yellow
- Number of cores: 4
- Conductor cross-section: 10 mm²
- Conductor diameter: 4.0 mm
- Average sheath thickness: 2.2 mm
- Maximum outer diameter: 23.6 mm
- Perm current rating in air 30°C: 75 A
H07BQ-F 5G10
Nexans ref. 116234009
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Conductor diameter: 4.0 mm
- Average sheath thickness: 2.3 mm
- Maximum outer diameter: 25.9 mm
- Perm current rating in air 30°C: 75 A
H07BQ-F 2 x 16
Nexans ref. 116080109
- Core identification: Blue, brown
- Number of cores: 2
- Conductor cross-section: 16 mm²
- Conductor diameter: 5.0 mm
- Average sheath thickness: 2.1 mm
- Maximum outer diameter: 22.8 mm
- Perm current rating in air 30°C: 115 A
H07BQ-F 3G16
Nexans ref. 116132009
- Core identification: Blue, brown, green/yellow
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Conductor diameter: 5.0 mm
- Average sheath thickness: 2.3 mm
- Maximum outer diameter: 24.7 mm
- Perm current rating in air 30°C: 100 A
H07BQ-F 4G16
Nexans ref. 116184009
- Core identification: Brown, black, grey, green / yellow
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Conductor diameter: 5.0 mm
- Average sheath thickness: 2.3 mm
- Maximum outer diameter: 27.0 mm
- Perm current rating in air 30°C: 100 A
H07BQ-F 5G16
Nexans ref. 116236009
- Core identification: Blue, brown, black, grey, green / yellow
- Number of cores: 5
- Conductor cross-section: 16 mm²
- Conductor diameter: 5.0 mm
- Average sheath thickness: 2.5 mm
- Maximum outer diameter: 30.0 mm
- Perm current rating in air 30°C: 100 A
Description
Description
Standards
-
Product2014/68/EU; HD 22.10
-
TestEN 50267-2-1; EN 50267-2-2; IEC 60332-1; IEC 60754-1; IEC 60754-2
Use and installation method
Reference Guide EN 50565:
They can be used both indoors and outdoors, in dry, damp or wet conditions. Suitable for heavy-duty uses and to power industrial and farm machinery. For connections undergoing moderate mechanical stresses, such as those in power tools (drills, circular saws, electrical home appliances) and heaters, as long as they do not touch hot parts and are not exposed to heat radiation. Avoid skin contact if they are used at high operating temperatures. Suitable to be used for fixed installations on temporary building fronts and workmen’s shelter at work sites. Suitable up to 1000 V A.C. for fixed installations and duly shielded (in ducts and equipment). Not suitable for underground laying, even if shielded.
Reference Construction Products Regulation 305/2011 EU and Standard EN 50575:
The cable is suitable for the supply of electricity in buildings and other civil engineering works.
Special features
Good resistance to mechanical stress and abrasion.
Good flexibility and behaviour at low temperatures.
Good resistance to UV (ISO 4892-2).
Absence of halogens. Sea water resistant.
Installation conditions
- Minimum installation temperature: -40°C
- Recommended minimum bending radius: 6 times the cable diameter for mobile use, 4 times for static use
- Recommended maximum tensile stress: 15 N/mm² of the cross-section of the copper for mobile use, 50 N/mm² for static use.
Construction
- Conductor: class 5, flexible, plain copper wire
- Insulation: EPR rubber compound, quality EI6
- Filler (optional): LS0H rubber, penetrating between the cores
- Sheath: LS0H TMPU polyurethane
- Colour: orange
- LS0H = Low Smoke Zero Halogen
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
LTC IEMMEQU ◄HAR► H07BQ-F [form.] Eca [order number] [year] Made in Italy [metric]
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania