RG26H1M16X 12/20(24)kV - 3 x 1 x 240
Certifications and labels
RG26H1M16X 12/20(24)kV - 3 x 1 x 240
Suitable for energy transmission between transformer rooms and big power users; mostly suitable for premises with fire risk, and places where appliances, electrical (switch) boxes and instruments are operating and whose safeguard is fundamental. For laying on air, into tube or open pass.
Read more- Nexans ref. : 586149106
Description
Description
Standards
-
ProductCEI 20-13; CEI-UNEL 35334; HD 620; IEC 60502-2
Use and installation method
Suitable for energy transmission between transformer rooms and big power users; mostly suitable for premises with fire risk, and places where appliances, electrical (switch) boxes and instruments are operating and whose safeguard is fundamental. For laying on air, into tube or open pass.
In case of UV exposure, appropriate protection is required.
Can be laid underground, complying with art. 4.3.11 of CEI 11-17 standard.
Reference Construction Products Regulation 305/2011 EU and Standard EN 50575:
The cable is suitable for the supply of electricity in buildings and other civil engineering works.
Installation conditions
- Minimum installation temperature: 0°C
- Recommended minimum bending radius: 21 times the cable diameter
- Recommended maximum tensile stress: 60 N/mm² of the cross-section of the copper
Construction
- Bundled three-core cables, insulated with HEPR rubber of G26 quality, with reduced thickness and maximum operating temperature of 105°C.
- In case of high temperature is allowed a 10% overload in continuous operation and/or higher margins in critical situations than traditional cables.
- Conductor: class 2, compact stranded wire, plain copper
- Semiconductor layer: extruded
- Insulation: rubber compound, G26 quality, Pb free (HD 620 DIH 2)
- Semiconductor layer: extruded, cold stripping
- Screen: plain copper wires with helically wounded copper tape
- Sheath: LS0H thermoplastic, M16 quality
- Colour: red
- LS0H = Low Smoke Zero Halogen
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Marking
Pb free LA TRIVENETA CAVI RG26H1M16 SLIMPOWER PLUS HT105 12/20 kV Cca-s1b,d1,a1 [form] [year] [traceability] [metric] FASE 1/2/3